Background: Hyperhidrosis (excessive sweating, OMIM %114110) is a complex disorder with multifactorial causes. Emotional strains and social stress increase symptoms and lead to a vicious circle. Previously, we showed significantly higher depression scores, and normal cortisol awakening responses in patients with primary focal hyperhidrosis (PFH). Stress reactivity in response to a (virtual) Trier Social Stress Test (TSST-VR) has not been studied so far. Therefore, we measured sweat secretion, salivary cortisol and alpha amylase (sAA) concentrations, and subjective stress ratings in affected and non-affected subjects in response to a TSST-VR.
Method: In this pilot study, we conducted TSST-VRs and performed general linear models with repeated measurements for salivary cortisol and sAA levels, heart rate, axillary sweat and subjective stress ratings for two groups (diagnosed PFH (n = 11), healthy controls (n = 16)).
Results: PFH patients showed significantly heightened sweat secretion over time compared to controls (p = 0.006), with highest quantities during the TSST-VR. In both groups, sweating (p < 0.001), maximum cortisol levels (p = 0.002), feelings of stress (p < 0.001), and heart rate (p < 0.001) but not sAA (p = 0.068) increased significantly in response to the TSST-VR. However, no differences were detected in subjective ratings, cortisol concentrations and heart rate between PFH patients and controls (pall > 0.131).
Conclusion: Patients with diagnosed PFH showed stress-induced higher sweat secretion compared to healthy controls but did not differ in the stress reactivity with regard to endocrine or subjective markers. This pilot study is in need of replication to elucidate the role of the sympathetic nervous system as a potential pathway involved in the stress-induced emotional sweating of PFH patients.
Advances in eye tracking technology have enabled the development of interactive experimental setups to study social attention. Since these setups differ substantially from the eye tracker manufacturer’s test conditions, validation is essential with regard to the quality of gaze data and other factors potentially threatening the validity of this signal. In this study, we evaluated the impact of accuracy and areas of interest (AOIs) size on the classification of simulated gaze (fixation) data. We defined AOIs of different sizes using the Limited-Radius Voronoi-Tessellation (LRVT) method, and simulated gaze data for facial target points with varying accuracy. As hypothesized, we found that accuracy and AOI size had strong effects on gaze classification. In addition, these effects were not independent and differed in falsely classified gaze inside AOIs (Type I errors; false alarms) and falsely classified gaze outside the predefined AOIs (Type II errors; misses). Our results indicate that smaller AOIs generally minimize false classifications as long as accuracy is good enough. For studies with lower accuracy, Type II errors can still be compensated to some extent by using larger AOIs, but at the cost of more probable Type I errors. Proper estimation of accuracy is therefore essential for making informed decisions regarding the size of AOIs in eye tracking research.